DHSIP Source Input Wall Plate
2. Wiring/Installation
Wiring for the DHSIP consists of a single run of Cat-5
wire between the DHTP1 Amplifi ed Touch Pad or
DH46X Digital Audio Router and the mounting loca-
tion for the DHSIP.
Note: Do not run Cat-5 wires closer than 12"
from high voltage wires.
T-568A Wiring Standard
All Cat-5 connections in a DH44-based system use
the industry standard T-568A wiring scheme as il-
lustrated in Figure 2.1. RJ-45 connectors are used to
terminate Cat-5 wires at both ends.
1 2 3 4 5 6 7 8
12 34 56 78
GREEN/WHITE
GREEN
ORANGE/WHITE
BLUE
BLUE/WHITE
ORANGE
BROWN/WHITE
BROWN
Shown tab
down
Figure 2.1: T-568A Wiring Standard